pHمتر هانا ایتالیا

COMPANY : HANNA, ITALY.
 

 BENCH TOP PH METER HI 2210 & HI 2211

HI 2211

HANNA’s new HI 2211 is a microprocessor based pH, mV and temperature benchtop meter. It features an extra large LCD that displays pH or mV and temperature simultaneously. The extra large LCD (6.25” x 1.5”) can be viewed from a distance in a lab.

This instrument can measure pH from -2.00 to 16.00 and can be calibrated at 1 or 2 points using 5 standard buffers. During calibration, prompts on the LCD guide the user through the process. Temperature compensation of the pH measurement can be automatic or manual between -9.9 to 120°C.

HI 2211 features a dual mV range (±399.9 or ±2000 mV) which can be used for ISE measurements, ORP measurements or to check the offset and slope of the pH electrode. Other features include a measurement memory function and a reading stability indicator. The HI 2211 is supplied with an HI 1131B glass body combination pH electrode, HI 7662 temperature probe, electrode holder, power adapter and buffer solutions to get you started.

HI 2210

For less demanding applications, HANNA’s HI 2210 includes all of the features of the HI 2211 with the exception of mV mode.

 

Brouchure 


SOM CODE : 1462/221
M
odel :
COMPANY : HANNA, ITALY.

PH/DC/MV ORP BENCH METER, GLP,RS 132.

Calibration CheckTM pH Meters

A pH electrode, when it is properly manufactured and is kept clean, will retain its physical characteristics for a long time. A common problem associated with pH measurements is the use of a pH electrode that has not been properly cleaned. This is very important because during calibration the instrument assumes that the electrode used is clean, and the standardization curve created during the calibration process will remain the same until the next calibration. pH meters on the market today will allow an offset of approximately ± 60 mV. The deviation from 0 mV is not unusual; in fact, it represents the true characteristics of the pH electrode. The deviation from 0 mV becomes a problem if it is the result of calibrating a dirty electrode. 

 

    Brouchure 

 

 

 
 Range   pH / 0C

-2.00 to 16.00 / -20.0 to 120.0

 mV/ppm  ±699.9; ±2000 
 Resolution   pH/ 0C  0.01 /  0.1 
 mV/ppm  0.1 (±699.9); 1 (±2000) 
 Accuracy  pH/ 0C  ±0.01 /
 mV/ppm  ±0.2 (±699.9); ±1 (±2000) 
 Typical EMC Deviation   + 0.01 pH; +0.50C;+0.3 mV; +1% F.S.
 pH Calibration  Automatic 1 or 2 points (pH 1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45)
 Temperature Compensation  Manual (MTC) or Automatic (ATC) temperature compensation from -20.0 to 120.0°C
 Electrode  glass body, single junction refillable cell, BNC + pin (included)
 Temperature probe  stainless steel probe (included)
 Power supply  12VDC adapter (included)
 Dimensions  240 x 182 x 74 mm (9.4 x 7.1 x 2.9”)
 Weight  1.1 Kg (2.5 lb.)

 

 

Model : HI 221


SOM CODE : 1462/301
M
odel : pH301
COMPANY : HANNA, ITALY.

GLP Bench pH/mV/Ion/0C Meter.
The pH calibration can be performed at 1, 2 or 3 points with 6 memorized pH values.

The opto-isolated RS232 is bi-directional, so that the user can operate the meter from the computer key-board. The pH 301 logging function can be used in the pH, mV and ISE modes. The logging interval is user-selectable. The memory is capable 
of retaining up to 99 different lots of up to 8000 samples.

 SOM CODE  1462/301
 Model  pH 301
 Range   pH / 0C

 -1.999 to 19.999 pH; -9.9 to 120.00C;

 mV/ppm  +1999.9 mV; 0.001 to 19999
 Resolution   pH/ 0C  0.01 & 0.001 pH; 0.10C
 mV/ppm  0.1 mV; 0.001;0.01; 0.1; 1
 Accuracy  pH/ 0C  + 0.002 pH; +0.50C
 mV/ppm  +0.1 mV ; +1% F.S.
 Typical EMC Deviation   + 0.01 pH; +0.50C;+0.3 mV; +1% F.S.
 pH Calibration  1,2 or 3 points with 6 memorized buffers.
 Temperature Compensation  Automatic or manual from -9.9 to 1200
 Electrode  HI 1131B
 Temperature probe  HI7669/2W with 1 m cable.
 Power supply  12VDC adapter
 Dimensions  280 x 200 x 75 mm
 Weight  1.3 Kg.

   Brouchure 


SOM CODE : 1462/302
M
odel : pH302+HI76405
COMPANY : HANNA, ITALY.

pH/mV/DC PRINTING METER WITH ELECTRODE.
The pH 302 fulfills the needs of general purpose and analytical laboratories for a single instrument to 
measure pH, millivolt (mV), Oxidation Reduction Potential (ORP), plus specific ions (ISE).
The oversized display is easy to read and present step-by-step guidance for calibration. 

Instructions are also provide on the display to correct calibration errors and guarantees optimal performance 
while performing your measurements. Advance memory features also enable you to recall calibration data to 
comply with Good Laboratory Practices (GLP) protocols.

Programmable Functions :
- Sampling cycle - set the sample number, time and date.
- Custom calibration - calibrate the meter using nonstandard buffer values
- GLP Compliance - prints calibration data with date, time, pH offset and slope
- Time Study 1 - log and print pH, mV, and temperature to a pre-set interval.
- Time Study 2 - log and print pH, mV, and temperature to a pre-set parameter.
- Alarms - set upper and lower pH or mV limits
- International - choice different languages for printed data.
- ISE - print the ion concentration for pH values.
- Connectivity - sets up communication with your computer.

 SOM CODE 1462/302
 Model  pH 302
 Range   pH 

 0.00 to 14.00

 mV  +399.9 (ISE) ; +1999 (ORP)
 oC  -9.9 to 120.0
 Resolution   pH/ 0C  0.01pH &  0.10C
 mV  0.1(ISE) ; 1(ORP)
 Accuracy  pH/ 0C  + 0.01 pH; +0.50C
 mV  +0.3 (ISE); +1(ORP) 
 Typical EMC Deviation   + 0.01 pH; +0.50C;+0.3 mV; +1% .
 pH Calibration  1or 2 points with 3 memorized buffers.
 Temperature Compensation  Automatic or manual from -9.9 to 1200
 Electrode  HI 1131B combination, glass body, refillable, 
 BNC connector (included)
 Temperature probe HI7669/2W, thermistor type with 1 m cable.
 Input Impedance 1012 Ohm
 Inputs  BNC/Reference/ATC
 Output  Bi-Directional RS232 opto-isolated
 Power supply 12VDC adapter
 Environment  0 to 500C; RH 95%
 Dimensions  280 x 200 x 75 mm
 Weight  1.3 Kg.

 

   Brouchure 

Model : pH302


SOM CODE : 1462/211  
Model : pH211
COMPANY : HANNA, ITALY.

pH/mV  Bench Meter With Electrode, Probe & Solution.
The new pH211 have been designed to be simple without sacrificing accuracy. meters measures the pH from 0 to 14 and temperature from 0 to 100 with 0.01 pH and 0.50C accuracy. The pH211 can also measures mV in two ranges of +399.9 and +1999 mV in conjunction with ISE's and ORP electrodes. The large display shows pH or mV and temperature at same time.

 SOM CODE 1462/211
 Model  pH 211
 Range  pH / 0C

 0.00 to 14.0 pH; 0.0 to100.00C;

 mV  +399.9 mV (ISE); +1999 mV (ORP)
 Resolution   pH / 0C  0.01 pH; 0.10C
 mV  0.1 mV (ISE); 1 mV (ORP)
 Accuracy  pH / 0C  + 0.01 pH; +0.50C
 mV  +0.2 mV (ISE); +1 mV (ORP)
 Typical EMC Deviation   + 0.03 pH; +0.30C;+2 mV
 pH Calibration  Automatic 1 or 2 points with 5 memorize buffer.
 Temperature Compensation  Automatic from 0 to 1000C
 Electrode  HI 1131B
 Temperature probe HI7669/2W with 1 m cable.
 Power supply 12VDC
 Dimensions  240 x 182 x 74 mm
 Weight  1.1 Kg.

 

   Brouchure 

Model : pH211
 

 


SOM CODE : 1462/209.
Model : pH209
COMPANY : HANNA, ITALY.

pH/mV  Bench Meter For School With Electrode.
The pH offset and slope are manually adjustable in order to display the calibration concept and the electrode characteristic to the students. Measurement can be performed for pH with manual temperature compensation as well as for REDOX (Reduction Oxidation Potential). The selected temperature is displayed to ensure better accuracy.
The LCD displays the temperature comprehensively while manually compensating for its effects.

Features :
- Simple 2-Button Operation.
- Manual Calibration.
- Long Battery Life.

 SOM CODE 1462/209
 Model  pH 209
 Range   pH 

 0.00 to 14.0 

 mV  +1999
 Resolution   pH  0.01 
 mV  1 
 Accuracy  pH  + 0.01
 mV  +1
 Typical EMC Deviation   + 0.03 pH; +2 mV
 pH Calibration  Automatic 1 or 2 points through offset and 
 slope knobs
 Temperature Compensation  Automatic from 0 to 1000C
 Electrode  HI 1332B
 Temperature Impedance  1012 ohm
 Power supply  12VDC
 Dimensions  240 x 182 x 74 mm
 Weight  1.0 K g.

 

  Brouchure 

Model : pH209


SOM CODE : 1462/110
Model : HI9025C
COMPANY : HANNA, ITALY.

pH/mV/DC Meter Waterproof  Micro 0.00 To 14.00 pH .
HI 9025 microprocessor-based pH meters in waterproof casings. HI 9025 measures pH, 
ion concentration and ORP in the mV range.

Features :
- Ready functions.
- Rugged, Waterproof Construction's
- Dual level display with Graphic  symbol.

Specifications :

 SOM CODE  1462/110
 Model  HI 9025C
 Range pH  0.00 to 14.00
 Resolution pH  0.01
 Accuracy  + 0.01
 Typical EMC  + 0.01
 Temperature 
 Compensation
 Automatic or Manual from   
 0 to 1000C
 Dimensions  196 x 80 x 60 mm
 Weight  425 g.


   Brouchure 


SOM CODE : 1462/23
Model : HI9210N
COMPANY : HANNA, ITALY.

pH Meter With Electrode waterproof  Portable.
The HI 9210N is heavy-duty pH meter is designed to provide laboratory result and accuracy under harsh industrial conditions. The unit can be calibrated at any pH buffer value.

 SOM CODE  1462/23
 Model  HI 9210N
 Range   pH

 0.00 to 14.0 pH

 Temperature  0.0 to 70.00C
 Resolution   pH  0.01
 Temperature   0.10C
 Accuracy  pH  + 0.02
 Temperature   +0.50C
 Typical EMC 
 Deviation
 pH  + 0.02
 Temperature  +0.50
 pH Calibration  Manual 2 points through trimmers.
 Temperature Compensation  Automatic from 0 to 700C
 Electrode  HI 1217D
 Battery Type/Life  4x1.5V AA/ 2000 hours
 Dimensions  196 x 80 x 60 mm
 Weight  320 g.

 

  Brouchure 

 


SOM CODE : 1462/31.
Model : HI991301
COMPANY : HANNA, ITALY.

pH/EC/TDS/DC Meter With Water Proof Case & Electrode.

Features
:
- 4 instruments in one : pH, conductivity, TDS and temperature all in one meter with a single probe.
- Tailor made for your application : Customized pH/EC calibration, select EC/TDS conversion factor and temperature 
  coefficient and choose the temperature scale that best fits your application.
- Easy of use, accuracy and durability : Two button operation, microprocessor based, rugged instrument and probe.

 SOM CODE 1462/31
 Model  HI 991301N
 Range 

 0.00 to 14.00 pH; 0.0 to 60.00C;
 0.00 to 19.99 mS/cm (EC); 0.00 to 10.00 pt. (TDS)

 Resolution   0.01pH; 0.10C; 0.01mS/cm; 0.01 pt.
 Accuracy  + 0.01pH; + 0.50C; + 2% Full Scale (EC/TDS)
 Typical EMC Deviation  + 0.3 pH; + 10C; + 2% Full Scale (EC/TDS)
 Temperature 
 Compensation
 pH : Automatic from 0 to 600C
 Probe  HI 1288 pH/EC/TDS probe with built-in 
 temperature sensor
 Battery Life/Type  500 hours approx. continuous use/4 x 1.5V AAA
 Dimensions  143 x 80 x 38 mm
 Weight  320 g.

Brouchure 

 


SOM CODE : 1462/32
Model : HI991300
COMPANY : HANNA, ITALY.

PH/EC/TDS/DC METER W/WATER PROOF CASE & ELECTRODE, RANGE PH 0 - 14, 0-3999US EC, 0 - 2000PPM TDS..

HANNA® offers you a choice of 2 meters to meet your exacting requirements. HI 991300 and HI 991301 both measure